MV heads
Products for safely terminating and connecting power cables to equipment or overhead lines, ensuring reliable insulation and protection.
Connector angle head type CSE 250
For terminating and connecting single-core polyethylene-insulated cables with a return conductor in the form of copper wires, such as YH(A)KXS, XH(A)KX(S), XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y*, with a rated voltage of 6/10 kV, 8.7/15 kV, and 12/20 kV.
Straight connector head type CSD 250
For terminating and connecting single-core polyethylene-insulated cables with a return conductor in the form of copper wires, of types YH(A)KXS, XH(A)KXS, XUH(A)KXS, XRUH(A)KXS*, with a rated voltage of 6/10 kV, 8.7/15 kV and 12/20 kV.
EUETH type overhead heat shrink head
For terminating single-core cables with polyethylene insulation of the type YH(A)KXS, XH(A)KX(S), XUH(A)KXS, XRUH(A)KXS with a rated voltage of 8.7/15 kV, 12/20 kV.
Connector type CSE 250 angled
Screened angle connector head (90°) with capacitive measuring point designed for terminating and connecting single-core polyethylene insulated cables with a copper wire screen of the YH(A)KXS, XH(A)KX(S), XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y* type with a rated voltage of 6/10 kV, 8.7/15 kV and 12/20 kV with a copper wire screen with switchgears, transformers, motors, equipped with bushings, connectors and type A sockets.
Straight connector type CSD 250
Screened straight connector head (180°) with capacitive measuring point designed for terminating and connecting single-core polyethylene insulated cables with a copper wire screen of type YH(A)KXS, XH(A)KXS, XUH(A)KXS, XRUH(A)KXS* with a rated voltage of 6/10 kV, 8.7/15 kV and 12/20 kV with switchboards, transformers, motors, equipped with insulator bushings, connectors and type A sockets.
Straight connector type CSE 400
Screened angled connector head (90°) with capacitive measuring point designed for terminating and connecting single-core polyethylene insulated cables with a copper wire screen of type YH(A)KXS, XH(A)KXS, XUH(A)KXS, XRUH(A)KXS* with a rated voltage of 8.7/15 kV, 12/20 kV and 18/30 kV with switchgears, transformers, motors, equipped with insulator bushings, connectors and type B sockets.
EUITH type indoor heat shrink head
For terminating single-core cables with polyethylene insulation of the type YH(A)KXS, XH(A)KX(S), XUH(A)KXS, XRUH(A)KXS with a rated voltage of 8.7/15 kV, 12/20 kV.
Connector type CST/CSC New
The coupling head (CSC) is used to implement double connection of cables to one bushing without using additional coupling elements. The connector head (CST) cooperates with bushings type C, rated current 630/1250 A, in accordance with the standards PN-EN 50180 and PN-EN 50181.
Heat shrink overhead type EUETH
Head designed for terminating single-core cables in polyethylene insulation type YH(A)KXS, XH(A)KX(S), XUH(A)KXS, XRUH(A)KXS with rated voltage of 8.7/15 kV, 12/20 kV. Technical assessment of the product for compliance with the PN-E-06401-05:1990 and PN-HD 629.1 S2:2006 standards.
EUITH indoor heat shrink
Head designed for terminating single-core cables in polyethylene insulation type YH(A)KXS, XH(A)KX(S), XUH(A)KXS, XRUH(A)KXS with rated voltage of 8.7/15 kV, 12/20 kV. Technical assessment of the product for compliance with the PN-E-06401-05:1990 and PN-HD 629.1 S2:2006 standards.
Cold shrink overhead type E3UERF
The head is designed for terminating single-core power cables with polyethylene insulation of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS type with a rated voltage of 8.7/15 kV, 12/20 kV.
Cold shrink overhead type E3UERF
The head is designed for terminating single-core power cables with polyethylene insulation of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS type with a rated voltage of 8.7/15 kV, 12/20 kV.