Medium voltage
Cold shrink JUPRF type through (plastic-plastic)
The joint is designed to connect single-core power cables with polyethylene insulation of the YH(A)KX(S) type. XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 12/20 kV.
Heat shrinkable through type JUPTH…RSM (plastic-plastic)
Joint designed for connecting single-core cables with polyethylene insulation of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 8.7/15 kV and 12/20 kV.
JTPPTH (paper-paper) heat shrinkable pass-through
Joint designed for connecting and repairing three-core paper-insulated cables of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA types with a rated voltage of 8.7/15 kV and 12/20 kV.
Heat shrink transition type JTMPTH (paper-plastic)
Joint designed for connecting and repairing a three-core paper-insulated cable of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA type with three single-core polyethylene-insulated cables of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 8.7/15kV and 12/20kV.
GMT type pass-through belt (plastic-plastic)
Joint designed for connecting single-core cables with polyethylene insulation of type YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y with rated voltage of 8.7/15 kV and 12/20 kV. Technical assessment of the product for compliance with the PN-E-06401-04:1990 standard.
Universal tape-resin type J3SI 24 U (paper-paper/paper-plastic)
As a TRANSITION JOINT designed to connect and repair a three-core paper insulated cable of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA type with three single-core polyethylene insulated cables of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 8.7/15 kV and 12/20 kV.
Ribbon-resin pass-through type J3SI 24 CPI (paper-paper)
Joint designed for connecting and repairing three-core paper-insulated cables of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA type with a rated voltage of 8.7/15 kV and 12/20 kV.
Tape-resin transition type J3SI 24 CPI-CSU (paper-plastic)
Joint designed for connecting and repairing a three-core paper-insulated cable of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA type with three single-core polyethylene-insulated cables of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 8.7/15 kV and 12/20 kV.
Universal tape-resin type J3SI 24 U (paper-paper/paper-plastic)
As a TRANSITION JOINT designed to connect and repair a three-core paper insulated cable of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA type with three single-core polyethylene insulated cables of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 8.7/15 kV and 12/20 kV.
Universal tape-resin type J3SI 24 U (paper-paper/paper-plastic)
As a TRANSITION JOINT designed to connect and repair a three-core paper insulated cable of the H(A)Kny, H(A)KnFtA, H(A)KnFty, H(A)KnFpy, H(A)KnFpA type with three single-core polyethylene insulated cables of the YH(A)KX(S), XH(A)KXS, XUH(A)KXS, XRUH(A)KXS, NA2XS(F)2Y type with a rated voltage of 8.7/15 kV and 12/20 kV.